The Bogen ZPM3 is a telephone-compatible zone paging
module with all-call and talk back capabilities serving up to
three one- or two-way paging zones. The ZPM3 can also be
used in a paging system independent of a telephone system.
The ZPM3 works with self-amplified or central-amplified paging systems. A background music source can be connected
directly to the ZPM3, or to a separate amplifier that can be
used to supply background music to all unpaged zones.
Built-in DIP switches are used to select the field-programming mode, enable/disable the pre-announce and confirmation tones, and set the paging mode (one-way or talk back)
of each zone.
Field-programming is used to assign individual zones to the
paging zone groups, night ringer zone group, and shift
change/emergency-call zone group*. Field-programming is
also used to enable/disable the privacy beep for two-way
zones, select the shift change/emergency-call tone, and
inhibit all-call operation.
A control is included to adjust the volume of the preannounce, confirmation, and shift change/emergency-call
tones. Separate controls are provided to adjust the night
ringer tone and background music volume. All volume controls are screwdriver-adjustable. 3 Zone paging plus All-Call
3 Field-programmable paging zone groups
(1-3 zones in each)
One-way and two-way paging (talk back operation
requires TBA15 Talk Back amplifier)
Direct connection to page ports (requires contact
closures), loop-start and ground start trunks
Connection to an analog station line (station port) possible
when used with a suitable telephone access module,
e.g., Bogen Model TAMB2
100W total power handling capacity
Background music input
DIP switches select zone type (one way or talk back),
talk battery (24V/48V), and tone options
Built-in night ringer in all zones or group of three
user-selected zones
Shift change or emergency-call (with alert tone) in all
zones or group of three user-selected zones*
Programmable All-Call inhibit and privacy beep for
talk back zones
Screw terminal block connections
Separate volume controls for tones, night ring, and
background music
Works with self-amplified or central-amplified paging
systems
Optional battery backup
24V power supply required; Bogen Model PRSLSI
power supply recommended
Terminals provided for connection to an additional 48V
power supply when 48V talk battery operation required
(Bogen PRS48 power supply recommended)
Registered under Part 68 of FCC rules
Includes flanges with keyhole slots for wall-mounting